For machines with limited installation space. Mechanical seal, so prime the suction chamber before the first start and do not run dry for more than 30 seconds.
Flow in L/min · head in m · immersion in mm · weight in kg. Other voltages and immersion depths can be built to order.
| Model | Motor W | Flow 50 Hz | Flow 60 Hz | Head 50 Hz | Head 60 Hz | Outlet | Immersion mm | Weight kg |
|---|---|---|---|---|---|---|---|---|
| ACP-61A | 60 | 20 | 25 | 2 | 2 | 3/8" | — | 7.5 |
| ACP-101A | 100 | 30 | 36 | 2 | 2 | 3/8" | — | 9 |
| ACP-181A | 180 | 53 | 70 | 3 | 3 | 1/2" | — | 12 |
| ACP-251A | 250 | 85 | 120 | 4 | 4 | 3/4" | — | 13 |
| ACP-401A | 400 | 125 | 170 | 5 | 5 | 1" | — | 14.5 |
| ACP-1101A | 1100 | 190 | 230 | 6 | 6 | 1 1/2" | — | 32 |
Protection IP44 (IP54 on 1101A). Mechanical seal — prime before first start; no dry running over 30 seconds.
| Model | L | L1 | L2 | L3 | TL | ØR1 | ØLA | ØLB | PE |
|---|---|---|---|---|---|---|---|---|---|
| ACP-61A | 56 | 16 | 74.5 | 114.5 | 205 | 93 | 132 (132) | 130 (150) | 2-PS 3/8" |
| ACP-101A | 56 | 16 | 74.5 | 114.5 | 205 | 93 | 132 (132) | 150 (150) | 2-PS 3/8" |
| ACP-181A | 75.5 | 16 | 96.5 | 133 | 245.5 | 121 | 160 (167) | 164 (170) | 2-PS 1/2" |
| ACP-251A | 71.5 | 16 | 96.5 | 133 | 245.5 | 121 | 160 (167) | 170 (170) | 2-PS 3/4" |
| ACP-401A | 86.5 | 15 | 104.5 | 194 | 313.5 | 145 | 180 (180) | — | 2-PS 1" |
| ACP-1101A | 124.5 | 28 | 160 | 205 | 393 | 172 | 220 (220) | — | 2-PS 1 1/2" |
Dimensions in mm. Values in parentheses apply to ACP-61A / 101A.
Send the model, voltage and immersion depth. We confirm price, packing and lead time within one working day.