Operating limits, materials, installation notes and the pump/distributor matching table.
| Lubricant | Oil 30–220 cSt; grease NLGI #000–#1 |
| Oil temperature | 80 °C maximum |
| Grease temperature | -20 to 70 °C (ARU-R) |
| Motor | 1-phase 100/200 V, 110/220 V; DC 24 V (AGP-MG10) |
| Protection | IP44 where stated |
| Tank | Steel; 1.8 / 3.0 / 6.0 / 12 / 20 L |
| Outlet | PT 1/8" to PT 1/4"; PF for grease |
| Cycle | Intermittent; do not run continuously |
| AMGP-01 / 013 / 015 | DB proportional or ARD/PVO quantitative |
| AMGP-NS | ARD-340/350, PVO metering valves |
| AMGP-03/05 | High-flow systems, multi-point |
| AGP-MG10 | PVG distributors |
| AGP-15 | ARU-R progressive distributors |
| ARD-340/350 | Oil, 2–5 outlets |
| ARU-R | Grease, 4–12 outlets |