The largest flow in the range, with a 2-inch outlet and up to 5.5 kW. Built for high-volume chip flushing and the biggest machining centres.
Flow in L/min · head in m · immersion in mm · weight in kg. Other voltages and immersion depths can be built to order.
| Model | Motor W | Flow 50 Hz | Flow 60 Hz | Head 50 Hz | Head 60 Hz | Outlet | Immersion mm | Weight kg |
|---|---|---|---|---|---|---|---|---|
| ACP-1800BMF | 1800 | 300 | 400 | 10 | 12 | 2" | 242 | 45 |
| ACP-2500BMF | 2500 | 400 | 400 | 10 | 20 | 2" | 295 | 46 |
| ACP-4000BMF | 4000 | 450 | 500 | 10 | 20 | 2" | 348 | 50 |
| ACP-5500BMF | 5500 | 480 | 550 | 10 | 20 | 2" | 401 | 57 |
Protection IP54. Designed for 1–2 cSt coolant; keep viscosity low for full flow.

ACP-BMF · 50/60 Hz
Water-soluble coolant, 20 °C, 2 cSt unless stated.
| Model | L | L1 | L2 | L3 | L4 | TL | ØR1 | PE |
|---|---|---|---|---|---|---|---|---|
| ACP-1800BMF | 242 | 47 | 314 | 30 | 150 | 556 | 180 | PS 2" |
| ACP-2500BMF | 295 | 47 | 331 | 30 | 202 | 626 | 180 | PS 2" |
| ACP-4000BMF | 348 | 47 | 376 | 30 | 255 | 724 | 180 | PS 2" |
| ACP-5500BMF | 401 | 47 | 447 | 30 | 308 | 848 | 180 | PS 2" |
Dimensions in mm.

Annotated outline drawing from catalogue p.32. Dimensions in mm.
Send the model, voltage and immersion depth. We confirm price, packing and lead time within one working day.